The outstanding feature of this product is that multi-elements can be analysed simultaneously. It is very suitable for analysing multiple components in one sample. It uses similar analysis mode to that of ICP. It can greatly increase analysis efficiency and save sample volume. In addition to multi-element analysis, it can also analyse one single component, working in the same mode as a flame atomic absorption spectrophotometer.
7800 Multi-element Atomic Absorption Spectrophotometer
Description
Main Features:
- Simultaneously analyse 4-6 elements within one minute (similar speed to ICP).
- Fast analysis, similar to the speed of ICP, test result of multiple components come out simultaneously by one sampling.
- Freely combine the multiple elements according to the requirements of analysis.
- Save sample volume for multiple components analysis.
- Rapid change of gas flow, grating rotation, slit and hollow cathode lamps.
- Unique optical design greatly increases the sensitivity in visible range.
- Excellent mechanical and optical system plus outstanding software ensure the measurement accuracy.
Specifications
- Wavelength range: 190-900nm
- 6-lamp turret: 1 lamp working, and 3 lamps preheating
- Wavelength repeatability: ±0.1nm
- Wavelength accuracy: ±0.2nm whole range
- Photometric range: 0-2.5Abs
- Resolution: spectral bandwidth = 0.2nm, can separate Mn two lines (279.5nm and 279.8nm), valley/peak energy ratio<20%
- Spectral bandwidth: 0.1, 0.2, 0.4, 0.7, 1.0, 2.0nm
- Static baseline drift: ≤0.002ABS/30min (Cu)
- Weight: 80kg
- Dimension: 500*450*430mm
- Grating: 1800lines/mm
- D2 background correction: background signal =1Abs, correction capability ≥50 times self-reversal background correction.
Graphite Furnace
- Graphite furnace atomization device is an electrothermal atomizer that increases the sensitivity of most metal elements from mg/L to μg/L
- Advanced optical controlled temperature programming system, realize automatic full power heating at atomization stage.
- Heating condition setup: drying, ashing, atomization and two heating modes.
- Temperature range: ambient-3000℃
- Temperature control mode: voltage feedback mode for drying and ashing, voltage or optical control feedback for atomization
- Characteristic concentration: Cu<1.0×10-10g, Cd<1.0×10-12g
Auto Sampler
- Automatic curving function: do not need manual set of calibration curves. Prepare a standard solution, then the sampler will automatically set the calibration curve and measure.
- Intelligent residual removal function: do not need artificial judgement and operation. It will automatically tell whether there are residuals and remove residuals to eliminate cross-contamination.
- Intelligent dilution function: fully automatic dilution. According to sample concentration, the instrument will automatically give dilution ratio, match to the best measurement area and automatically finish dilution and measurement. The whole process needs no manual intervention.
- In-tube visual system: monitor injection and drying process. All tiny subtleties of drying come into your view, enabling fast and accurate setup of ashing temperature.
- Quality control: intelligent analysis quality control technology, calibrate blank and quality control sample at regular intervals and monitor the precision of test results.
Hydride Generator
- Essential analytical equipment for environmental monitoring, food hygiene, quality inspection, commodity inspection, and drinking water monitoring.
- Highly automated: only one start key. Sampling, generating, measuring and cleaning will all be done by pressing the button.
- Unique electrothermal quartz absorption tube: Small and exquisite device, heated quickly, convenient to install, with stabled temperature, more than 10 times lifetime than flame, free of gas consumption, analytical method can be rapidly changed once it is cooled down.
- Adopt advanced flow injection technology. Sample reaction is more uniform. The stability is improved. RSD<2%
- Measurement rate: 100times/hour
- Single sampling volume: <2mL
Flame System
Item | 5800 | 7800 |
Wavelength Range | 190-900nm | 190-900nm |
Grating | 1800lines/nm | 1800lines/nm |
Wavelength Repeatability | ±0.1nm | ±0.1nm |
Wavelength Indication Error | Whole range ±0.2nm | Whole range ±0.2nm |
Optical System | Czerny-Turner system, integrated optical platform, fully sealed | Czerny-Turner system, integrated optical platform, fully sealed optical system |
Resolution | Spectral bandwidth =0.2nm can separate Mn two lines (279.5nm and 279.8nm, valley/peak | Spectral bandwidth =0.2nm can separate Mn two lines (279.5nm and 279.8nm, valley/peak energy ratio <20% |
Spectral Bandwidth | D2 (background signal =1Abs, background correction capability | 0.1nm, 0.2nm, 0.4nm, 0.7nm, 1.0nm, 2.0nm |
Static Baseline Drift | Integrating structure of suspended internal and external | ≤0.002ABS/30min (Cu) |
Background Calibration Technology | 4-lamp turret (4 lamps can be
preheated simultaneously) |
D2 (background signal =1Abs, background correction capability ≥50 times |
Instrument Design | Integrating structure of suspended internal and external optical path | Integrating structure of suspended internal and external optical path |
Lamp Turret | 4-lamp turret (4 lamps can be
preheated simultaneously) |
6-lamp turret (6 lamps can be
preheated simultaneously) |
Burner Head | Air-acetylene burner head
(100mm, optional 50mm nitrous oxide-acetylene is available) |
Air-acetylene burner head (100mm) |
Nebulizer | High-efficiency glass nebulizer | High-efficiency glass nebulizer |
Ignition Dynamic Baseline Drift | ≤0.004ABS/30min(Cu) | ≤0.004ABS/30min(Cu) |
Characteristic Concentration (Cu) | ≤0.025μg/ml/1%
(Absorbance>0.8ABS) |
≤0.02μg/ml/1%
(Absorbance>0.8ABS) |
Detection Limit | Cu≤0.008ug/ml | Cu≤0.004ug/ml |
Repeatability (Cu) | ≤0.5% | ≤0.5% |
Gas Flow Control | Manual | Auto |
Ignition Method | via buttons on the control panel | PC control |
Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched |
Background Calibration Technology | SR and D2, correct 1A background. When background signal =1Abs, correction
capability ≥50 times |
SR and D2, correct 1A background. When background signal =1Abs, correction capability ≥50 times |
Dimension | 700*550*530mm | 700*550*530mm |