5E-C5808 Automatic Calorimeter
5E-C5508 is used to determine the calorific value of solid and liquid combustibles including oil, coal, coke, foodstuffs and biomass products. The calorific value is a crucial characteristic for each substance, also the key point to calculate the price of coal, so it will directly affect the economic benefits of the customers. This technique is widely applied in power plants, coal mines, metallurgy, chemical industry, commercial inspection, scientific research, etc.
Description
Models Available:
5E-C5808 Automatic Calorimeter (Ignition Wire)
5E-C5808J Automatic Calorimeter (Laser Ignition Technology)
Optional Configuration:
Lens paper
Pellet press
Halogen Resistant Oxygen Vessel
Standard Configuration:
Main analyzer
Standard CV bomb -1 Unit
Computer
Crucibles
Benzoic Acid
O-ring kit
Tool kit
Features
1. Patented laser ignition technology allowing easier and faster sample preparation, no ignition wire or cotton thread is needed(Available in 5E-C5808J model only)
2. 8min fast analysis for one sample
3. Automatic oxygen vessel lifting
4. Automatic oxygen charging and venting
5. Intelligent temperature control of the jacket and the water tank, the water constant temperature stability of the jacket reaches to 0.02℃
6. Small space occupied with compact design
7. Intelligent diagnosis and safety protection function
2. 8min fast analysis for one sample
3. Automatic oxygen vessel lifting
4. Automatic oxygen charging and venting
5. Intelligent temperature control of the jacket and the water tank, the water constant temperature stability of the jacket reaches to 0.02℃
6. Small space occupied with compact design
7. Intelligent diagnosis and safety protection function
Specification
Model | 5E-C5808 / 5E-C5808J Automatic Calorimeter | |
Conforms to Method | AS 1038.5, ASTM D5865,ASTMD 240, ASTM D5865, ASTM D4809, ASTM E711, BIS 1350, BS EN 15400, GB/T 213,GB/T 30727, ISO 1928, ISO 9831, ISO 18125 | |
Precision (1g Benzoic Acid) | 0.05% RSD * | |
Measuring range | Up to 50000J | |
Heat Capacity Stability | ≤0.2% within one year | |
Temp.Resolution | 0.0001℃ | |
Control Ability | 2 Units/ 1 PC available | |
Analysis Time per Sample | 8mins | |
Jacket Type | Isoperibol | |
Ignition Method | Ignition Wire / Patented Laser Ignition Technology – Available in 5E-C5808J model only | |
Bomb Identification | Yes | |
Balance Connection | Available | |
Network Connection | Available | |
Bucket Filling | Automatic | |
Oxygen Filling | Automatic | |
Bomb Vessel Lifting | Automatic | |
Structure | Benchtop | |
Power Supply | Single phase, AC220V±10%, 50/60Hz, ≤500w | |
Net Weight | 50kg | |
Dimensions(L×W×H) | 480mm×500mm×420mm | |
*Test Condition: 1. Ambient temp.20℃±1℃,humidity75%±5% 2. No strong interference source nearby 3. Clean water circuit with distilled water 4. Refer to the precision of ten acceptable calibration test runs |