5E-C5500 Automatic Calorimeter
Description
Standard Configuration:
Main analyzer: Controlling Unit and Chiller
Standard CV bomb
Computer
Handle Oxygen Charger
Crucibles
Ignition Wire
Benzoic Acid
O-ring kit
Tool kit
Optional Configuration:
Lens paper
Pellet press
Bench-top oxygen charger
Halogen Resistant Oxygen Vessel
Features:
True Isoperibol Calorimeter
The jacket surrounding the vessel is kept at constant temperature with an accuracy to 0.1℃ during analysis.Mechanical supports for the vessel are made of a very lowthermal conductivity plastic. To minimize convention,water is added on the sides,top and bottom of the bucket.
High Automation and Efficiency
1. Dynamic method available, without compromising accuracy or precision.
2. Second oxygen vessel and sample can be prepared while the current sample is being analyzed.
3. Two calorimeters can be controlled by one computer.Sample mass can be transferred to PC directly.
Optimized Design for Reliable Test Result
1. A reliable quantitative measuring cup ensures stable water volume of the bucket.
2. Closed-loop water circulation assures the purity of water system without any additional solution.
3. Filter in the bucket purify the water in circulation system.
4. Visible water level indicates the water volume, making it easy to feed sufficient water anytime to minimize the influence of water loss.
Specification
Model | 5E-C5500 Automatic Calorimeter | |
Conforms to Method | AS 1038.5, ASTM D240, ASTM D5865, ASTM D4809, ASTM E711, BIS 1350, BS EN 15400, GB/T 213,GB/T 30727, ISO 1928, ISO 9831,ISO 18125 | |
Precision (1g Benzoic Acid) | 0.05% RSD * | |
Measuring range | Up to 50000J | |
Temp.Resolution | 0.0001℃ | |
Control Ability | 2 Units/ 1 PC available | |
Analysis Time per Sample | Dynamic method:10mins; Classical method:15mins | |
Jacket Type | Isoperibol | |
Jacket Type | Isoperibol | |
Heating Capacity Stability | ≤0.2% within one year | |
Balance Connection | Available | |
Network Connection | Available | |
Bucket Filling | Automatic | |
Oxygen Filling | Semi-Automatic | |
Structure | Benchtop or Vertical | |
Bomb Vessel Lifting | Manual | |
Power Supply | Single phase, AC220V±10%, 50/60Hz, ≤500w | |
Net Weight | Bench top: 75kg | |
Vertical type: 103kg | ||
Dimensions(L×W×H) | Bench top: 480mm×500mm×420mm (Analysis unit) 370mm×500mm×420mm (Temp. control unit) |
|
Vertical: 480mm×500mm×940mm | ||
*Test Condition: 1. Ambient temp.20℃±1℃,humidity75%±5% 2. No strong interference source nearby 3. Clean water circuit with distilled water 4. Refer to the precision of ten acceptable calibration test runs |